White stucco Spanish Colonial Revival buildings with terracotta roofs glow at dusk on a hillside dotted with oak trees.

Heat Pump Repair in San Rafael, CA

Tell us about the job

Takes about a minute. No obligation.

RepairHeat PumpMarin County, CA
Step 1 of 2

What ZIP code is the job in?

Winters here stay mild

Overnight lows in San Rafael average 43°F through December, January and February. Your heat pump isn't fighting hard freezes to keep the house warm, so it isn't working as hard as the same unit would in a colder county.

That usually means a fixable problem

A heat pump that hasn't been run ragged tends to hold up well mechanically. When one here starts acting up, it's more often a part that's failed or worn than a system that's been worked to death. That's usually worth repairing rather than replacing.

9 months
October through June, your system heats
43°F
the average winter night it heats against
71°F
the average summer afternoon it cools against
Isometric line illustration of a cutaway single-story house showing interior rooms with beds and furniture, ceiling ductwork connected to an indoor air handler, and an outdoor condenser unit linked by refrigerant lines.

Heat here starts up in October, after sitting idle since spring.

The first cold snap in San Rafael finds whatever part was already weak.

Wind and hail here are unremarkable, and so is the power bill behind the fix

Power costs 31.97 cents a kWh statewide
122 damaging wind events from 2015 to 2024
11 hail events from 2015 to 2024

A heat pump fails for a handful of ordinary reasons. The reversing valve sticks and the system gets stuck in one mode, heating when it should cool or the other way around. A contactor pits and burns from years of cycling on and off, until one day it doesn't close. Refrigerant leaks slowly at a fitting or coil, and the system runs longer and longer to make the same heat before it finally can't keep up. The defrost board or sensor fails, and the outdoor coil ices over and stays iced. Capacitors weaken with age and stop giving the compressor or fan motor the kick it needs to start. None of this is about the weather working the unit over. It's parts wearing out the way parts do, on a schedule that has more to do with age and run time than with how cold it got outside.

If your heat pump is original to the house, ask how much life it has left

Half the homes in Marin County were built in 1967 or earlier. If your heat pump came with a house that age, it's had years to rack up repairs, and this one may not be the last. Worth asking how much life the system has left before you fix what just failed.

Find a contractor
A dark gray heat pump unit mounted on a concrete pad next to a house with gray siding and a stone veneer wall.

Most of what fails is a part, not the system

A heat pump runs in both directions, which gives it more ways to fail than a straight air conditioner has. Before deciding anything, find out what actually quit. A stuck reversing valve, a burned contactor, a weak capacitor, that's a repair every time, and fixing one doesn't shorten the life of what's left. The one part that changes the math is the compressor. It sits at the center of the system, and it costs enough that a tech will stop and ask whether an older unit is worth putting a new one into. That's the moment to weigh the system's age against the repair, not before. Short of a failed compressor, the usual answer is to fix what broke and keep running.

A weak start wears the compressor down

When a capacitor weakens, the compressor still starts, but it draws more current to do it. That extra strain heats the windings every time it kicks on. Keep running it that way and the compressor is what eventually fails, the one part at the center of the whole system.

Ice on the coil feeds on itself

If the defrost board stops triggering a defrost cycle, frost builds on the outdoor coil. Ice blocks airflow across the coil, so the system works harder to pull heat from outside, which cools the coil further and grows more ice. Left alone, the coil can ice solid and starve the system of airflow entirely.

Most people notice a heat pump problem before they can name it. The air coming from the vents turns lukewarm, or the system runs and runs without the house ever feeling warm. Sometimes it switches on and shuts off again within a minute, over and over, which wears on the parts that are already struggling. A hissing or bubbling sound near the outdoor unit usually points to refrigerant escaping somewhere it shouldn't. Ice on the outdoor coil that doesn't melt off on its own is another one, especially if it's been building for more than a day. If the outdoor fan isn't spinning but the indoor side is still pushing air, that's worth a call before the compressor takes the damage instead.

A tech starts outside at the unit. Gauges go on to check refrigerant pressure, and a meter checks the current draw on the compressor and fan motor. That tells most of the story before a panel even comes off. The indoor air handler gets checked too, since the problem can sit on either side of the line. The tech will ask when the trouble started and what it looks like, because a system that short cycles points somewhere different than one blowing lukewarm air. Once the failed part is found, you get a plain answer on what's wrong and whether it's worth fixing given the age of the unit.