Electricity here isn't cheap
California homes paid 31.97 cents per kilowatt-hour in 2024. An air conditioner losing efficiency doesn't just run, it runs at that rate.
Takes about a minute. No obligation.
California homes paid 31.97 cents per kilowatt-hour in 2024. An air conditioner losing efficiency doesn't just run, it runs at that rate.
A clogged filter, a dirty coil, or a low refrigerant charge all make the compressor work harder to produce the same cooling. That extra draw shows up on the bill every time the system runs, not just once.

NOAA nClimDiv, 1991–2020 normals
Half the homes in Sacramento County were built in 1981 or later.
A system that age still has years ahead of it, and a yearly check is what gets it there.




A yearly check is what keeps that rate from creeping up. A technician cleans the coil, checks the charge, and clears what the filter missed, the things that make a compressor strain if left alone. That's the visit, once a year, before summer starts. Skip it and the system doesn't fail right away. It just draws more every afternoon it runs, at 31.97 cents a kilowatt-hour, all summer long.
A system built with a newer home still has most of its life ahead. A yearly check before summer is what keeps it running the way it did on day one, instead of losing a little more each year.
Find a contractorOnce May hits, this system runs into a 92 degree afternoon most days, five months straight. A check before then is the one chance to catch a weak capacitor or a coil going dirty before it has to work through that kind of heat. Wait until July and the same part has already been straining through it for weeks.
A technician checks the start and run capacitor against its rating. One that's drifted below spec will still kick the compressor on most mornings, so the system seems fine until the afternoon it doesn't start at all. That reading is the only way to catch it first.
Dust and fine debris settle between the fins of the outdoor coil where airflow pulls them in, not on the surface you can see from outside the cabinet. A coil like that still blows cold air, it just rejects heat slower, so the compressor runs longer for the same result.
A tune-up checks the refrigerant charge, cleans the coils, tests the capacitor and tightens the electrical connections.
A tune-up is a specific list, not a glance at the unit. The technician checks refrigerant charge against what the system calls for, since too little and the compressor runs long and still falls short. The capacitor and contactor get tested under load, because those are the parts that strand a system on a hot start rather than fail with warning. The condensate drain gets cleared, since a clogged one backs up and shuts the system down on its own. Blower wheel, coil fins, and the filter all get checked for the buildup that makes a system push harder for the same cooling. None of that shows up from outside the cabinet. It shows up as a reading that's off, or a part that's starting to drift.